Nobody looks at cabling until something stops working – and then everyone is on a ladder, lifting ceiling tiles and guessing which blue cable goes where.

We install cabling you will never have to think about: Cat6 and Cat6A copper to every desk and camera, fiber between floors and buildings, everything labelled, tested and certified before we leave.

15–20 years
Cat6 / Cat6A cable
Optical fiber
Patch panels & ODFs

is how long your cabling stays in the walls – it has to be done right once

15–20 yearsis how long your cabling stays in the walls – it has to be done right once
Why it matters

Cabling stays in your walls for twenty years

Cabling is the one part of your network you install once and live with for 15–20 years. Neat, certified structured cabling makes moves, additions and fault-finding quick; poor cabling causes intermittent faults that waste hours and are expensive to fix behind ceilings and walls.

How it works

From the main rack to every outlet

Tap any part of the drawing to see what it does.

MAIN BUILDING – MDFFLOORS – IDFREMOTE HALL / WAREHOUSE Main rack (MDF) ODF & splices Floor rack 1 Floor rack 2 Patch panels Remote rack Work outlets
  1. 01Fiber backbone runs from the main rack to every floor and building
  2. 02Copper Cat6/Cat6A runs from floor racks to each outlet
  3. 03Every link is spliced, terminated, tested, certified and labelled
Technical depth

Cabling standards & media we work with

01

Horizontal copper: Cat6 / Cat6A

Cat6 for 1 Gb/s to the desk; Cat6A for 10 Gb/s, Wi-Fi 6E/7 access points and high-power PoE. Up to 90 m permanent link.

02

Single-mode & multi-mode fiber

OM3/OM4 multi-mode inside buildings; OS2 single-mode between buildings and over long distances – kilometres, not metres.

03

Backbone & campus topology

A star from the main distribution frame (MDF) to intermediate frames (IDF) on each floor or hall, with fiber backbones between them.

04

Fusion splicing & OTDR testing

Fiber is fusion-spliced for the lowest loss, then tested with an OTDR trace to show the length and loss of every joint.

05

Certification & labelling

Every copper link is certified with a cable analyser; every outlet, patch-panel port and cable is labelled to a clear scheme.

06

Pathways & containment

Cable trays, trunking and conduits sized with spare capacity, separated from power cables to avoid interference.

What’s included

Everything in the scope

✓

Copper Cat6/Cat6A horizontal cabling

✓

Single-mode and multi-mode fiber backbones

✓

Fusion splicing and OTDR testing

✓

Racks, patch panels and cable management

✓

Labelling and link-test reports

Equipment we supply & install

Cables, fiber and the racks that hold them

Cat6 / Cat6A cableSolid copper, LSZH options
Optical fiberOS2 / OM3 / OM4, armoured outdoor
Patch panels & ODFs24/48-port, loaded or modular
Racks & cable managementWall and floor racks
Fiber transceivers1G / 10G SFP and SFP+

Also available

Cat6/Cat6A cable & keystone jacksIndoor/outdoor armoured fiberODF, pigtails & patch cordsFloor and wall racksTrunking, cable trays & conduits

Drawings are representative. We recommend exact models and brands after the site survey.

The Dexign Box difference

Why our cabling passes inspection first time

✓
Certified test reports

You receive a test report for every copper link and an OTDR trace for every fiber – proof the job was done right.

✓
Own splicing team

Fusion splicing, OTDR and certification by our own technicians, not sub-contractors.

✓
Clean, documented racks

Colour-coded patching, labels and as-built drawings make future changes fast for anyone.

✓
Planned for growth

Spare fiber cores, rack space and tray capacity are built in from day one.

1Survey
2Design
3Supply
4Install
5Test & certify
6Support

Where you’ll find it

  • New buildings and fit-outs
  • Factory floor-to-office links
  • Campus and multi-building sites
  • Data center and server rooms

Questions we answer on the survey

  • What do you need now, and what can wait?
  • How will it connect to the systems you already have?
  • What will it cost to run and maintain each year?
  • Which local rules and inspections apply to your site?
Brands we work with for this solution
Cisco logoHuawei logo

Planning structured cabling & optical fiber? Let’s talk it through.

Free site survey · reply within one working day

0344-8499944 Send a request →