Structured Cabling & Optical Fiber
Nobody looks at cabling until something stops working – and then everyone is on a ladder, lifting ceiling tiles and guessing which blue cable goes where.
We install cabling you will never have to think about: Cat6 and Cat6A copper to every desk and camera, fiber between floors and buildings, everything labelled, tested and certified before we leave.
is how long your cabling stays in the walls – it has to be done right once
Cabling stays in your walls for twenty years
Cabling is the one part of your network you install once and live with for 15–20 years. Neat, certified structured cabling makes moves, additions and fault-finding quick; poor cabling causes intermittent faults that waste hours and are expensive to fix behind ceilings and walls.
From the main rack to every outlet
Tap any part of the drawing to see what it does.
- 01Fiber backbone runs from the main rack to every floor and building
- 02Copper Cat6/Cat6A runs from floor racks to each outlet
- 03Every link is spliced, terminated, tested, certified and labelled
Cabling standards & media we work with
Horizontal copper: Cat6 / Cat6A
Cat6 for 1 Gb/s to the desk; Cat6A for 10 Gb/s, Wi-Fi 6E/7 access points and high-power PoE. Up to 90 m permanent link.
Single-mode & multi-mode fiber
OM3/OM4 multi-mode inside buildings; OS2 single-mode between buildings and over long distances – kilometres, not metres.
Backbone & campus topology
A star from the main distribution frame (MDF) to intermediate frames (IDF) on each floor or hall, with fiber backbones between them.
Fusion splicing & OTDR testing
Fiber is fusion-spliced for the lowest loss, then tested with an OTDR trace to show the length and loss of every joint.
Certification & labelling
Every copper link is certified with a cable analyser; every outlet, patch-panel port and cable is labelled to a clear scheme.
Pathways & containment
Cable trays, trunking and conduits sized with spare capacity, separated from power cables to avoid interference.
Everything in the scope
Copper Cat6/Cat6A horizontal cabling
Single-mode and multi-mode fiber backbones
Fusion splicing and OTDR testing
Racks, patch panels and cable management
Labelling and link-test reports
Cables, fiber and the racks that hold them
Also available
Drawings are representative. We recommend exact models and brands after the site survey.
Why our cabling passes inspection first time
You receive a test report for every copper link and an OTDR trace for every fiber – proof the job was done right.
Fusion splicing, OTDR and certification by our own technicians, not sub-contractors.
Colour-coded patching, labels and as-built drawings make future changes fast for anyone.
Spare fiber cores, rack space and tray capacity are built in from day one.
Where you’ll find it
- New buildings and fit-outs
- Factory floor-to-office links
- Campus and multi-building sites
- Data center and server rooms
Questions we answer on the survey
- What do you need now, and what can wait?
- How will it connect to the systems you already have?
- What will it cost to run and maintain each year?
- Which local rules and inspections apply to your site?


Often installed together
Planning structured cabling & optical fiber? Let’s talk it through.
Free site survey · reply within one working day