Data Center & Server Solutions
Your server room holds the things you can't afford to lose: accounts, designs, ERP, email and months of camera footage. Yet it is often the hottest, dustiest corner of the building.
We design server rooms and small data centers that stay cool, stay powered and stay organised – with proper airflow, clean power, tidy cabling, monitoring and fire protection that won't damage the equipment.
uptime is the Tier III design target – reached through redundant power, cooling and design
When the server room stops, everything stops
Your servers hold your ERP, accounts, CCTV recordings and email. A server room that overheats, loses power or is hard to manage puts the whole business at risk. Good design gets power, cooling, cabling, monitoring and fire protection right from the start.
Power, cooling and racks working together
Tap any part of the drawing to see what it does.
- 01Cold air is delivered to the cold aisle; hot air is contained
- 02Online UPS and generator keep power clean and continuous
- 03Sensors and clean-agent suppression protect against heat, leaks and fire
Data center design elements
Hot / cold aisle layout
Racks face the same way so cold air enters the front and hot air leaves the back – cooling becomes far more efficient.
Redundant power (N+1 / 2N)
Dual power feeds, online UPS and generator backup so no single failure switches servers off.
Precision cooling
In-row or room precision air-conditioning controls temperature and humidity tightly, unlike comfort AC.
Spine-leaf fabric & virtualisation
High-speed switching between servers; virtualised hosts make better use of hardware.
Environmental monitoring
Temperature, humidity, water-leak and door sensors with SMS and email alerts.
Clean-agent fire protection
Early-warning smoke detection with gas suppression that does not damage equipment.
Everything in the scope
Rack and tower servers, SAN/NAS storage
Racks, aisle containment and cable management
Precision cooling and environmental monitoring
Redundant power with UPS and PDUs
Clean-agent fire suppression for server rooms
What goes into a reliable server room
Also available
Drawings are representative. We recommend exact models and brands after the site survey.
Why we build it as one project
Civil works, raised floor, power, cooling, racks, cabling, monitoring and fire protection – coordinated by one team.
Power and cooling sized for your growth, with load calculations documented.
We plan and run server moves over weekends or nights.
Alerts reach your team – and ours under AMC – the moment something drifts.
Where you’ll find it
- Corporate server rooms
- Hospital and bank data rooms
- Factory MES/ERP servers
- Disaster-recovery sites
Questions we answer on the survey
- What do you need now, and what can wait?
- How will it connect to the systems you already have?
- What will it cost to run and maintain each year?
- Which local rules and inspections apply to your site?





Often installed together
Planning data center & server solutions? Let’s talk it through.
Free site survey · reply within one working day
