Home/Safety & Fire Solutions/Fire Detection & Alarm
Fire Detection & Alarm

Gas Leak Detection

LPG and natural gas give no warning you can see. They collect quietly in a kitchen, boiler room or store – until a switch or spark sets them off. Gas leaks caused more than 1,300 fires in Punjab in 2025.

Fixed gas detectors raise the alarm at a tiny fraction of the explosive level, start the exhaust fans and shut the gas supply automatically – before anyone has to notice the smell.

LPG & CO
LEL 0%
Fixed gas detectors
ARMED
Gas control panels
Solenoid shut-off valves

are invisible killers – detection and automatic shut-off stop them early

LPG & COare invisible killers – detection and automatic shut-off stop them early
Why it matters

Invisible danger needs an automatic answer

Gas leaks caused over 1,300 fires in Punjab in 2025. LPG and natural gas collect unseen until a spark ignites them, and carbon monoxide poisons silently. Fixed gas detectors raise the alarm at a small fraction of the explosive level and can shut the gas supply and start exhaust fans automatically.

How it works

From the first trace of gas to shut-off

Tap any part of the drawing to see what it does.

KITCHEN · BOILER ROOM · LPG STORELEL 0% LPG detector (low)LEL 0% Natural gas / CO (high)ARMEDGas control panelSolenoid shut-off valveAlarm & exhaust fanMobile alert
  1. 01Detectors sense gas at a small % of the explosive level
  2. 02The controller warns and starts ventilation
  3. 03At high level the gas supply is shut off automatically
Equipment we supply & install

Detectors and valves

LEL 0%
Fixed gas detectorsLPG, NG, CO, H₂S, NH₃
ARMED
Gas control panelsMulti-channel
Solenoid shut-off valvesManual-reset
Alarms & beaconsLocal warning

Also available

Gas detectors & controllersSolenoid shut-off valvesExhaust interlocksCalibration kits

Drawings are representative. We recommend exact models and brands after the site survey.

Technical depth

Gas detection technologies

01

Catalytic & infrared (LEL) sensors

Measure flammable gas as a % of the Lower Explosive Limit – alarm long before an explosive mix forms.

02

Electrochemical toxic sensors

Detect CO, H₂S, NH₃ and other toxic gases in ppm.

03

Correct placement by gas density

LPG is heavier than air (detectors low); natural gas is lighter (detectors high).

04

Two-stage alarms & shut-off

Low alarm warns and starts ventilation; high alarm closes the solenoid valve.

05

Calibration & bump testing

Sensors drift – regular calibration keeps readings trustworthy.

What’s included

Everything in the scope

✓

LPG, natural gas and CO detection

✓

Toxic and process gas detection

✓

Automatic solenoid shut-off valves

✓

Exhaust fan and alarm interlocks

✓

Calibration and testing

The Dexign Box difference

Why our gas systems are set up right

✓
Gas-risk survey

We identify every source, the gas type and correct mounting height.

✓
Shut-off integration

Valves and exhaust fans wired and tested with the detectors.

✓
Calibration schedule

Calibration and bump tests under AMC with records.

✓
Linked to fire alarm

Gas alarms can report to the main fire panel and BMS.

1Survey
2Design
3Supply
4Install
5Test & certify
6Support

Where you’ll find it

  • Kitchens and canteens
  • Boiler and generator rooms
  • Chemical and pharma plants
  • Gas cylinder stores

Questions we answer on the survey

  • What do you need now, and what can wait?
  • How will it connect to the systems you already have?
  • What will it cost to run and maintain each year?
  • Which local rules and inspections apply to your site?
Brands we work with for this solution
Honeywell logo

Planning gas leak detection? Let’s talk it through.

Free site survey · reply within one working day

0344-8499944 Send a request →